PCV System: Operation

The PCV valve contains a spring loaded plunger. When engine starts, plunger is lifted in proportion to manifold vacuum, which pulls blow-by gases out of crankcase through PCV valve and into intake manifold where they mix with incoming air/fuel mixture. Fresh air enters crankcase from hose to valve cover.

Fig 1: Crankcase Ventilation System
G37814