ELD Replacement
- Do the battery terminal disconnection procedure (see BATTERY TERMINAL DISCONNECTION AND RECONNECTION ).
- Remove the upper cover (A), then remove the two positive (+) terminals (B).
- Remove the under-hood fuse/relay box (C) from the bracket.
- Remove the lower cover (A). A-
- Disconnect the ELD 3P connector (B).
- Remove the fuses (A and B).
- Release the three lock tabs (A), then remove the ELD (B).
- Install the parts in the reverse order of removal.
- Do the battery terminal reconnection procedure (see BATTERY TERMINAL DISCONNECTION AND RECONNECTION ).