Grind Complete
Includes: Remove carbon, check surfaces for warpage, reface or replace Valves, resurface Valve Seats and clean Valve Guides. Adjust Valves (where applicable).
| Applies To | Note | Standard Hours | Warranty Hours | Skill Level |
| In-Line4, w/California Emissions | Includes: Recover, Evacuate and Recharge Air Conditioning System. | 12.9 | | A |
| In-Line4, w/o California Emissions | Includes: Recover, Evacuate and Recharge Air Conditioning System. | 12.5 | | A |
| Combination Procedure: VALVE LIFTERS: Remove & Replace: |
| All | | 0.5 | | B |
| Combination Procedure: VALVE LIFTERS (REMOVED): Clean: |
| Each Additional | | 0.1 | | B |
| One | | 0.2 | | B |