Component Inspection
- Remove the oil pressure and oil temperature sensor.
(Refer to " REMOVAL ")
- Measure resistance between terminal 1 and terminal 4.
- Compare the measured resistance with the specification below.
Temperature Resistance (kΩ) °C °F -40 -40 125.53 - 136.70 -30 -22 93.26 - 104.65 -20 -4 63.89 - 71.23 -10 14 41.80 - 46.52 0 32 26.83 - 30.07 10 50 17.13 - 19.23 20 68 11.13 - 12.48 25 77 9.00 - 10.11 30 86 7.369 - 8.279 40 104 4.89 - 5.50 50 122 3.34 - 3.76 60 140 2.32 - 2.61 70 158 1.63 - 1.84 80 176 1.17 - 1.32 90 194 0.86 - 0.97 100 212 0.64 - 0.72 110 230 0.48 - 0.54 120 248 0.37 - 0.41 130 266 0.28 - 0.32 140 284 0.22 - 0.25 150 302 0.17 - 0.20 160 320 0.14 - 0.16