lemon-mirror:
Home >> Mazda >> 1983 >> B2000 Base >> Repair and Diagnosis >> Engine Performance >> System >> Spark Control System >> Component Testing >> Water THERMO Valve

Water THERMO Valve

Insert valve and thermometer in container of water. Heat water gradually and note temperature when air can be blown through valve. Valve should open at 122°F (50°C). If temperature does not meet specifications, replace water thermo valve.