lemon-mirror
:
Home
>>
Mazda
>>
2004
>>
RX-8 1.3 3
>>
Repair and Diagnosis
>>
Engine Performance
>>
Engine Control Systems
>>
Metering Oil Pump Switch Inspection
>>
Circuit Open/Short Inspection
>>
Short circuit
Short circuit
If there is continuity in the following wiring harnesses, there is a short circuit. Repair or replace the wiring harness.
Metering oil pump switch terminal A and body ground
Metering oil pump switch terminal A and power supply