EGR System: Testing: TD-Signal

Using a multimeter, connect positive lead to terminal 2 of plug connection for TD input. Measure voltage at idle speed. Voltage should be about 2.8 volts. If not okay, check activation of RPM sensor for engine. If there is no activation, replace sensor.