lemon-mirror:
Home >> Mitsubishi >> 2006 >> Raider XLS, RWD >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Electronic Control Modules >> Module - Transfer Case Control >> Operation >> Shift Attempt Limit

Shift Attempt Limit

To protect the transfer case system, the FCM will impose a limit on the number of shifts that can occur over a calibrated time period. The system will monitor the number of mode sensor position changes that occur in any 25 second time period. If the number of changes is 10 or greater, the system will go into a default mode. The default mode of operation for shifting is that the number of allowed changes permitted to occur will be 3 over each 15 second +/-100 msec calibrated window of time. After 5 minutes +/-100 msec, the motor can be assumed to have cooled down and the system will revert to normal operation. The following rules also apply to the shift limit: