lemon-mirror:
Home >> Porsche >> 1985 >> 944 Standard >> Repair and Diagnosis >> Engine Performance >> System >> DME System >> Testing >> DME Control

DME Control

  1. Reconnect the fuel pressure regulator vacuum hose. Disconnect the oxygen sensor. Connect the oxygen sensor harness connector terminal to ground.
  2. Check if the CO% level increases. If not, check wire from CU connector terminal 24 to oxygen sensor plug. If no problem is found, replace the oxygen sensor.
Fig 1: Diagram of 944 DME System Distributor Align distributor cap with its locking boss facing up.
G42096