lemon-mirror:
Home >> Acura >> 1995 >> NSX Automatic >> Repair and Diagnosis >> Electrical >> Starters >> Bench Testing >> Starter Field Winding

Starter Field Winding

  1. Check for continuity between brushes. If there's no continuity, replace armature housing.
  2. Check for continuity between each brush and armature housing (ground). See Fig 1 . If continuity exists, replace armature housing.
Fig 1: Testing Starter Field Winding
G00088975Courtesy of AMERICAN HONDA MOTOR CO., INC.