lemon-mirror:
Home >> Acura >> 1997 >> 2.2CL Automatic >> Repair and Diagnosis >> Electrical >> Charging Systems >> Generators & Regulators >> Bench Testing >> Rectifier Diodes

Rectifier Diodes

NOTE: Use an ohmmeter capable of checking diodes.
  1. Check for continuity between rectifier assembly terminal "B" and terminals P1-P5, and between terminals "E" and P1-P5. Refer to Fig 1. Note ohmmeter reading.
  2. Reverse leads, and repeat test. Continuity should exist only in one direction. If continuity is not as specified, replace rectifier assembly.
Fig 1: Identifying Rectifier Terminals
G96H06029Courtesy of AMERICAN HONDA MOTOR CO., INC.