Hazard Warning Switch Test
Check for continuity between specified switch terminals with switch in indicated position. See HAZARD WARNING SWITCH CONTINUITY TEST table. See Fig 1 . If continuity is not as specified, replace hazard warning switch. If continuity is as specified, check turn signal/hazard relay input. See TURN SIGNAL/HAZARD RELAY INPUT TEST under SYSTEM TESTS.
HAZARD WARNING SWITCH CONTINUITY TEST
| Switch Position | Continuity Between Terminals No. |
|---|---|
| Off | 2 & 9; 7 & 8 |
| On | 1, 2, 5 & 6 |
| On | 4 & 9; 7 & 8 |