lemon-mirror:
Home >> Acura >> 2000 >> Integra GS-R, 2D Coupe >> Repair and Diagnosis >> External Pages >> Different car >> Section 8 (Generators & Regulators) >> Bench Testing >> Rectifier Diodes

Rectifier Diodes

WARNING: This page is about a different car, the 2001 Acura Integra. However, it is still accessible from the selected car via links, so may be relevant.
  1. Check continuity between rectifier assembly terminal "B" and terminals P1-P5, and between terminal "E" and terminals P1-P5. See Fig 1 . Note ohmmeter reading.
  2. Reverse leads, and repeat test. Continuity should exist only in one direction. If continuity is not as specified, replace rectifier assembly.
Fig 1: Identifying Rectifier Terminals
G98A04258Courtesy of AMERICAN HONDA MOTOR CO., INC.