lemon-mirror:
Home >> Acura >> 2008 >> CSX Base, K20Z1 >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transmission >> Automatic Transmission >> System Description >> Electronic Control System >> Shift Control

Shift Control

The PCM instantly determines which gear should be selected by various signals sent from sensors and switches, and it actuates shift solenoid valves A, B, C, D, and E to control shifting transmission gear.

Shift solenoid valves are a normally closed type. Shift solenoid valve opens the port of shift solenoid valve pressure leading to shift valves while shift solenoid valve is turned ON by the PCM, and closes the port when shift solenoid valve is OFF.

The combination of driving signals to shift solenoid valves A, B, C, D, and E are shown in the table.

SHIFT SOLENOID VALVE REFERENCE CHART

Position Gear Position Shift Solenoid Valve
A B C D E
D and S Shifting from the N position OFF ON ON OFF OFF
Stays in 1st ON ON ON OFF OFF
Shifting gears between 1st and 2nd OFF ON ON OFF OFF
Stays in 2nd OFF ON OFF ON OFF or ON
Shifting gears between 2nd and 3rd OFF ON ON ON OFF or ON
Stays in 3rd OFF OFF ON OFF OFF or ON
Shifting gears between 3rd and 4th OFF OFF OFF OFF OFF or ON
Stays in 4th ON OFF OFF OFF OFF or ON
Shifting gears between 4th and 5th ON OFF OFF ON OFF or ON
Stays in 5th ON OFF ON ON OFF or ON
N Neutral OFF ON ON OFF OFF
R Shifting from the P and N positions OFF ON OFF OFF ON
Stays in reverse ON ON OFF OFF ON
Reverse inhibit control ON ON OFF OFF OFF
P Park OFF ON OFF OFF ON