VSA Off Switch Test/Replacement
- Remove the instrument fascia (see INSTRUMENT FASCIA REMOVAL/INSTALLATION ).
- Disconnect the multi switch 6P connector (A).
- On the switch side, check for continuity between the multi switch 6P connector terminals No. 4 and No. 6. There should be continuity when the button is pressed, and no continuity when the button is released.
- If the continuity is not as specified, replace the multi switch (with built-in VSA OFF switch) (A) from the instrument fascia (B).
- Install the multi switch (with built-in VSA OFF switch) in the reverse order of removal.