No Load Test

With starter on test bench, take readings of starter current, voltage and RPM. Readings should be within specifications.

STARTER NO LOAD TEST SPECIFICATIONS

Model Volts/Amps. RPM
208 xxx 11.5/35-55 6000-8000
211 xxx 11.5/30-50 6000-9000
212 xxx 11.5/35-55 6000-8000
311 xxx 11.5/30-50 5500-7500
312 xxx 11/55-85 8500-10,500
317 xxx N/A N/A
362 xxx 11.5/65-95 6500-8500
BRUSH LENGTH & SPRING TENSION SPECIFICATIONS

Application In. (mm) Ozs. (g)
208 xxx .52 (13) 40-50 (1150-1350)
211 xxx .52 (13) 40-46 (1150-1300)
212 xxx N/A N/A
311 xxx .52 (13) 40-46 (1150-1300)
312 xxx .39 (10) 29-32 (800-900)
314 xxx .52 (13) 40-46 (1150-1300)
317 xxx N/A N/A
362 xxx .61 (15.5) 40-46 (1150-1300)