lemon-mirror:
Home >> Audi >> 1987 >> 5000 CS, Automatic >> Repair and Diagnosis >> Engine Performance >> System >> Digital Control System - Turbo & QUATTRO >> Operation >> Fuel Control >> Oxygen Sensor

Oxygen Sensor

Oxygen sensor is mounted in exhaust pipe in front of catalytic converter. Oxygen sensor measures oxygen content in exhaust gas. Heating element is used to quickly warm oxygen sensor. Minimum operating temperature of oxygen sensor is 572°F (300°C). A rich mixture will send a signal in excess of .5 volt while a lean mixture will give signal of less than .5 volt.