Sensor Range Charts
NOTE:
Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
COOLANT TEMPERATURE SENSOR RESISTANCE TEST
| Temperature |
Ohms |
| 68°F (20°C) |
2200-2600 |
| 104°F (40°C) |
1000-1400 |
| 176°F (80°C) |
285-315 |
| 212°F (100°C) |
180-220 |
AIR TEMPERATURE SENSOR RESISTANCE TEST
| Temperature |
Ohms |
| 68°F (20°C) |
400-700 |
MASS AIRFLOW SENSOR VALUES
| Terminals |
Volts |
| 2 & 4 |
1.0-7.5 |
| 1 & 2 |
0.3- 1.1 |
Courtesy of AUDI OF AMERICA, INC. OXYGEN SENSOR VALUES
| Application |
Ohms |
| 2.3L |
3-15 |