Safety Lockout Switch
Remove safety lockout switch and disconnect harness connector. Check continuity between switch terminals with switch in appropriate position. See SAFETY LOCKOUT SWITCH TEST table. See Fig 1 . If continuity is not as specified, replace safety lockout switch.
SAFETY LOCKOUT SWITCH TEST
| Switch Position | Check Between Terminal No. | Specification | |
|---|---|---|---|
| Off | |||
| 1 & 2 | No Continuity | ||
| 3 & 4 | No Continuity | ||
| On | |||
| 1 & 2 | Continuity | ||
| 3 & 4 | Continuity | ||