lemon-mirror:
Home >> Audi >> 2021 >> S8 >> Repair and Diagnosis >> Body & Frame >> Mirrors >> Driver Assistance Systems >> 98 Assistance Systems >> Rearview Camera System >> Rearview Camera System, Calibrating

Rearview Camera System, Calibrating

Special tools and workshop equipment required 

Calibration/adjustment must be performed if:

Preparing for Calibration

Fig 1: Identifying Overview Of Assembled Calibration Equipment
GWWA91-10524Courtesy of AUDI OF AMERICA, LLC
  1. Calibration Tool - Wheel Center Mounting: VAS6350/1A 
    • With wheel bolt adapter and measuring paddle
  2. Calibration Tool - Wheel Center Mounting: VAS6350/1A 
    • With wheel bolt adapter and measuring paddle
  3. Right Catch Bracket
    • To mount the Spacing Laser: VAS6350/2A  for the distance measurement
  4. Plastic Foot
    • Adjustable for adjusting the horizontal position of the Calibration Tool: VAS6350A 
    • Quantity: 3
  5. Calibration Tool - Linear Laser: VAS6350/3A 
    • With "laser protective eyewear"
    • On the Calibration Tool: VAS6350A 
    • Refer to Calibration Tool - Line Laser: VAS6350/3A  Owner's Manual for handling.
  6. Calibration Tool - Spacing Laser: VAS6350/2A 
    • For distance measurement
    • Refer to the Calibration Tool - Spacing Laser: VAS6350/2A  Operating Instructions for handling.
  7. Level
    • On the Calibration Tool: VAS6350A 
    • For checking the horizontal position
  8. Left Catch Bracket
    • To mount the Spacing Laser: VAS6350/2A  for the distance measurement
  9. Calibration Tool: VAS6350A 
    • Between the catch bracket on the calibration board and the Calibration Tool - Wheel Center Mountings: VAS6350/1A  , dimension -a- 1.40 m through 2.00 m.

Preliminary Work

Procedure 

Fig 2: Identifying Wheel Pick-Ups On Wheel Mounting Bolts At Rear Wheels
GWWN94-10685Courtesy of AUDI OF AMERICA, LLC

-- Check which hole circle the rims have.

-- Secure three suitable wheel bolt adapters for the wheel bolts on each Calibration Tool - Wheel Center Mountings: VAS6350/1A  .

-- Insert the measuring paddle at both Calibration Tool - Wheel Center Mounting: VAS6350/1A  and secure with the locking nut.

-- Place the Calibration Tool - Wheel Center Mountings: VAS6350/1A  onto the wheel bolts on both rear wheels.

-- Place the Calibration Tool - Wheel Center Mounting: VAS6350/1A  on the wheels so that any "anti-theft wheel bolts" are not connected to the wheel center mounting.

-- Adjust the measuring paddle using the locking nuts so that they move freely just above the floor.

-- Position the Calibration Tool: VAS6350A  at distance -a- to the rear wheels.

Fig 3: Positioning Calibration Device VAS 6350
GWWA96-10536Courtesy of AUDI OF AMERICA, LLC

-- Using the bubble level (level indicator) -arrow-, bring the Calibration Tool: VAS6350A  into a horizontal position by turning the plastic bases.

GWWN91-12608Courtesy of AUDI OF AMERICA, LLC

-- Wear "laser protective eyewear".

Fig 4: Identifying Laser -1- On Calibration Platform Set To Align Entire Calibration Platform With Vehicle
GWWA91-10525Courtesy of AUDI OF AMERICA, LLC

-- Turn on the Calibration Tool - Linear Laser: VAS6350/3A  -1- on the Calibration Tool: VAS6350A  .

-- Align the Calibration Tool: VAS6350A  so that the Calibration Tool - Linear Laser: VAS6350/3A  -1- strikes the center of the brand emblem on the rear lid.

Distance measurement of Calibration Tool: VAS6350A  to rear wheels:

-- Switch on the Calibration Tool - Spacing Laser: VAS6350/2A  .

The Following Display Appears 1 :

Fig 5: The Following Display Appears -1- :
GWWN91-12610Courtesy of AUDI OF AMERICA, LLC

The display -2- shows how to position the Calibration Tool - Spacing Laser: VAS6350/2A  .

GWWN91-12611Courtesy of AUDI OF AMERICA, LLC

-- Press the corresponding button.

-- Hold the Spacing Laser: VAS6350/2A  -2- for the distance measurement on one side of the calibration board flush to the catch bracket, as shown.

GWWN98-10007Courtesy of AUDI OF AMERICA, LLC

-- Push the measurement button briefly.

The laser switches on.

-- Make sure the "laser beam" for the distance measurement contacts the lower enlarged part of the measuring paddle -1-.

If that is not the case, then correct the measuring paddle -1- height using the clamping screw on the Calibration Tool - Wheel Center Mounting: VAS6350/1A  .

-- Use one hand to hold the Calibration Tool - Spacing Laser : VAS6350/2A  firmly in the catch bracket on the Calibration Tool: VAS6350A  ; the laser beam should be seen on the measuring paddle during this.

-- Then press the measurement button for the distance measurement briefly.

-- Note the value.

-- Repeat this measurement on the other side of the Calibration Tool: VAS6350A  in the same way for the rear wheel.

-- If both measured values are not the same, then readjust the Calibration Tool: VAS6350A  correspondingly until the distance values are the same on both sides.

-- Make sure the Calibration Tool - Line Laser: VAS6350/3A  strikes the center above the brand emblem and that the level indicator remains centered. Adjust if necessary.

Distance measurement of Calibration Tool: VAS6350A  to the workshop floor:

GWWN98-10008Courtesy of AUDI OF AMERICA, LLC

-- Measure the distance from the upper edge of the Calibration Tool: VAS6350A  to the floor, dimension -a-.

-- Make sure the Calibration Tool - Spacing Laser: VAS6350/2  is set correctly (attached to the front edge).

The display -2- shows how to position the Calibration Tool - Spacing Laser: VAS6350/2A  .

GWWN91-12611Courtesy of AUDI OF AMERICA, LLC

-- Press the corresponding button.

-- Then press the measurement button for the distance measurement briefly.

-- Note the measured distance from the upper edge of the Calibration Tool: VAS6350A  to the floor.

Height measurement from center of rearview camera lens to the wheel contact surface:

-- Use commercially available measuring tape to measure the height from the center of the rearview camera lens to the wheel contact surface.

-- Mark the determined height.

The determined distance and height dimensions must now be entered in "millimeters" in the Vehicle Diagnostic Tester.

Calibration Procedure

The following should not occur during the calibration procedure:

-- Connect the Vehicle Diagnostic Tester.

-- Switch the ignition on.

-- Select and start the Diagnostic  operating mode.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.

-- Switch off the ignition after successful calibration/adjustment.

-- Disconnect the Vehicle Diagnostic Tester from the diagnostic connection.

-- Disconnect the battery charger. Refer to BATTERY, CHARGING .