Free Running Test
With starter in test bench (follow test manufacturers instructions), take readings of starter current, voltage and RPM.
NOTE:
Starter must be mounted so as to prevent meshing of pinion and ring gear even in engaged position, also if starter has warmed up during previous tests, the RPM will be higher.
SPECIFICATIONS
| Brush Spring Tension | |||
|---|---|---|---|
| Application(1) | Lbs. (Kg) | ||
| 208 XXX | 2.54-2.98 (1150-1350) | ||
| 211 XXX | 2.54-2.98 (1150-1350) | ||
| 211 9XX | 2.38-2.69 (1080-1220) | ||
| 212 XXX | 2.38-2.69 (1080-1220) | ||
| 311 XXX | 2.54-2.87 (1150-1300) | ||
| 312 1XX | 1.76-1.98 (800-900) | ||
| 313 XXX | 2.54-2.87 (1150-1300) | ||
| 362 XXX | 2.54-2.87 (1150-1300) | ||
|
|||
MIN. BRUSH LENGTH
| Application | In. (mm) |
|---|---|
| 312 1XX | .394 (10) |
| 362 XXX | .611 (15.5) |
| All Other Starters | .512 (13) |
NOTE:
For performance test data, see Specification table.