Fuel Injection System - MOTRONIC CEC
>>
THERMOTIMER Resistance Specifications
>>
Notes
THERMOTIMER Resistance Specifications: Notes
THERMOTIMER RESISTANCE SPECIFICATIONS
Circuit Tested
Resistance
"G" to Ground
40-70 Ohms
"G" to "W" & "W" to Ground
Above 60°F (15°C)
Infinite
Below 60°F (15°C)
Zero