lemon-mirror:
Home >> BMW >> 1994 >> 850CSi >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Self Diagnostics >> Component Tests >> Oxygen Sensor >> Test Option

Test Option

Disconnect DME control unit from voltage supply for at least 5 minutes, then disconnect oxygen sensor and perform CO measurement again. If CO value approaches nominal value, oxygen sensor should be replaced and CO measurement repeated.