FZD Module Programming Error (61 16 16)
Publication date: 2016-08-01Reference number: 61 16 16
FZD MODULE PROGRAMMING ERROR
TECHNICAL SERVICE BULLETIN
| BMW: | G12 (7 Series) |
| GROUP: | General Electrical Systems B61 16 16 Technical Service |
SITUATION
During vehicle programming (vehicles with integration level 16-03-502 or below), the Roof Function Center module (FZD) programming aborts.
CAUSE
Software error in the FZD.
CORRECTION
Replace FZD after second unsuccessful programming attempt.
PROCEDURE
For vehicle that exhibits condition described in the situation:
- After first unsuccessful programming attempt, try to program the FZD a second time.
Was second attempt successful?
YES - repair is complete.
NO - replace FZD with appropriate part found in ETK.
- Reprogram vehicle
Note that ISTA/P will automatically reprogram and code all programmable control modules that do not have the latest software. For information on programming and coding with ISTA/P, refer to CenterNet / TIS / Technical Documentation / Diagnostics and Programming / Programming Documentation.
Always connect a BMW approved battery charger/power supply (SI B 04 23 10 ) .
WARRANTY INFORMATION
Covered under the terms of the BMW New Vehicle Limited Warranty for Passenger Cars and Light Trucks
Or:
Covered in conjunction with an "eligible repair" this is covered under the terms of the BMW Certified Pre-Owned Program.
Vehicle Programming and Coding
Control module failures that occur during programming:
- Please claim this consequential repair under the defect code for the repair that required the "initial" programming/encoding procedure.
| Defect Code: | KSD2 | As Noted Above |
Program the FZD a Second Time, First attempt Unsuccessful
| Labor Operation: | Labor Allowance: | Description: |
|---|---|---|
| 61 00 731 | Refer to KSD2 | Additional work after first termination while programming/encoding |
And, if necessary:
Replace FZD, Second Programming Unsuccessful (All except ALPINA)
| Labor Operation: | Labor Allowance: | Description: |
|---|---|---|
| 61 31 544 | Refer to KSD2 | Replacing roof switch cluster |
| And: | ||
| 61 00 732 | Refer to KSD2 | Additional work after second termination while programming/encoding |
Or:
Replace FZD, Second Programming Unsuccessful (ALPINA Only)
| Labor Operation: | Labor Allowance: | Description: |
|---|---|---|
| 61 99 000 | 2 FRU | Work time for replacing roof switch cluster |
| And: | ||
| 61 00 732 | Refer to KSD2 | Additional work after second termination while programming/encoding |
Work time labor operation code 61 99 000 is not considered a Main labor operation. Also, since the "work time" FRU allowance to be claimed is specified, a separate punch time is not required.
Refer to KSD2 for the corresponding flat rate unit (FRU) allowances.
Other Repairs
Control module failures that occur prior to programming:
- When covered under an applicable limited warranty, claim these repairs using the applicable defect code and labor operations in KSD2.