lemon-mirror:
Home >> BMW >> 2016 >> 740i >> Repair and Diagnosis >> Quick Lookups >> Technical Bulletins >> Technical Service Bulletins >> Body Interior >> FZD Module Programming Error (61 16 16)

FZD Module Programming Error (61 16 16)

Publication date: 2016-08-01
Reference number: 61 16 16

FZD MODULE PROGRAMMING ERROR

FZD MODULE PROGRAMMING ERROR

TECHNICAL SERVICE BULLETIN

Reference Number(s): SI B61 16 16, Date of Issue:  August 2016
BMW: G12 (7 Series)
GROUP: General Electrical Systems B61 16 16 Technical Service

SITUATION

During vehicle programming (vehicles with integration level 16-03-502 or below), the Roof Function Center module (FZD) programming aborts.

CAUSE

Software error in the FZD.

CORRECTION

Replace FZD after second unsuccessful programming attempt.

PROCEDURE

For vehicle that exhibits condition described in the situation:

  1. After first unsuccessful programming attempt, try to program the FZD a second time.

    Was second attempt successful? 

    YES - repair is complete.

    NO - replace FZD with appropriate part found in ETK.

  2. Reprogram vehicle

    Note that ISTA/P will automatically reprogram and code all programmable control modules that do not have the latest software. For information on programming and coding with ISTA/P, refer to CenterNet / TIS / Technical Documentation / Diagnostics and Programming / Programming Documentation.

    Always connect a BMW approved battery charger/power supply (SI B 04 23 10  )  .

WARRANTY INFORMATION

Covered under the terms of the BMW New Vehicle Limited Warranty for Passenger Cars and Light Trucks

Or:

Covered in conjunction with an "eligible repair" this is covered under the terms of the BMW Certified Pre-Owned Program.

Vehicle Programming and Coding

Control module failures that occur during programming:

  • Please claim this consequential repair under the defect code for the repair that required the "initial" programming/encoding procedure.
Defect Code:  KSD2  As Noted Above 

Program the FZD a Second Time, First attempt Unsuccessful

Labor Operation: Labor Allowance: Description:
61 00 731 Refer to KSD2 Additional work after first termination while programming/encoding

And, if necessary:

Replace FZD, Second Programming Unsuccessful (All except ALPINA)

Labor Operation: Labor Allowance: Description:
61 31 544 Refer to KSD2 Replacing roof switch cluster
And:
61 00 732 Refer to KSD2 Additional work after second termination while programming/encoding

Or:

Replace FZD, Second Programming Unsuccessful (ALPINA Only)

Labor Operation: Labor Allowance: Description:
61 99 000 2 FRU Work time for replacing roof switch cluster
And:
61 00 732 Refer to KSD2 Additional work after second termination while programming/encoding

Work time labor operation code 61 99 000 is not considered a Main labor operation. Also, since the "work time" FRU allowance to be claimed is specified, a separate punch time is not required.

Refer to KSD2 for the corresponding flat rate unit (FRU) allowances.

Other Repairs

Control module failures that occur prior to programming:

  • When covered under an applicable limited warranty, claim these repairs using the applicable defect code and labor operations in KSD2.