Programming Theft Deterrent System Components
If replacing a PCM with a replacement part, after programming, these modules will learn incoming fuel continue password immediately upon receipt of a password message. Once a password message is received and a password is learned, a learn procedure must be performed to change this password again. A PCM which has been previously installed in another vehicle will have learned the other vehicle's fuel continue password and will require a learn procedure after programming to learn current vehicle's password.
- Turn ignition on, engine off.
- Attempt to start engine, then release key to ON position (vehicle will not start).
- Observe SECURITY telltale, after approximately 10 minutes telltale will turn off.
- Turn ignition off and wait 5 seconds.
- Repeat steps 1 through 4 2 more times for a total of 3 cycles in 30 minutes. Vehicle is now ready to relearn Passlock™ sensor data code and/or passwords on next ignition switch transition from OFF to CRANK position.
- Start engine. Vehicle has now learned Passlock™ sensor data code and/or password.
- Using scan tool, clear any DTCs if needed.
NOTE:
Vehicle learns Passlock™ Sensor Data Code and/or password on next ignition switch transition from OFF to CRANK position. You must turn ignition off before attempting to start vehicle.