Removal Procedure
CAUTION:
Provide proper ventilation when working with fuel in enclosed areas where fuel vapors can collect. The lack of adequate ventilation may result in personal injury.
CAUTION:
Always wear safety goggles when working with fuel in order to protect the eyes from fuel splash.
NOTE:
Do Not handle the fuel sender assembly by the fuel pipes. The amount of leverage generated by handling the fuel pipes could damage the joints.
NOTE:
Clean all of the following areas before performing any disconnections in order to avoid possible contamination in the system:
- The fuel pipe connections
- The hose connections
- The areas surrounding the connections
- Relieve the fuel system fuel pressure. Refer to Fuel Pressure Relief Procedure .
- Remove the fuel sender assembly (1). Refer to Fuel Sender Assembly Replacement .
- Note the position of the fuel pump strainer (1) for installation.
- Support the reservoir with one hand and grasp the fuel pump strainer with the other hand.
- Pull the external fuel pump strainer off of the fuel pump.
IMPORTANT:
The modular fuel sender support assembly will spring-up when the locking ring is moved.