lemon-mirror:
Home >> Cadillac >> 1991 >> Seville Base >> Repair and Diagnosis >> Electrical >> Starter >> Starting System >> On-Vehicle Testing >> Starter No-Load Test

Starter No-Load Test

  1. Connect test equipment to starter. See Fig 1. Close switch and compare RPM, amperage and voltage readings with specifications. See STARTER NO-LOAD TEST SPECIFICATIONS table.
    CAUTION: DO NOT  apply more voltage than specified. Excessive voltage may cause armature to throw windings due to excessive speed.
  2. If current draw and RPM meet specification, starter motor is okay. If test indicates low free speed and high current draw, unit may have tight, dirty or worn bearings, shorted or grounded armature, bent armature shaft, or grounded fields.
  3. Failure to operate with high current draw indicates direct ground in terminal fields or frozen bearings. Failure to operate with no current draw indicates an open field circuit, open solenoid windings, open armature coils or broken brush springs.
  4. Low RPM and low current draw indicates high internal resistance due to poor connections, defective leads or dirty commutator. High free speed and high current draw indicate shorted fields.
Fig 1: Starter No-Load Test Connections
G3539Courtesy of GENERAL MOTORS CORP.
STARTER NO-LOAD TEST SPECIFICATIONS

Part Number Motor Amps (1) RPM
1998548 SD200 50-75 6000-11,900
1998579 SD300 70-110 6500-10,700
1998580 SD300 70-110 6500-10,700
1998591 SD300 70-110 6500-10,700
10455004 SD200 50-75 6000-11,900
10455006 SD250 45-74 8600-12,900
10455007 SD200 50-75 6000-11,900
10455010 SD210 55-85 7000-12,000
10455011 SD210 45-75 6000-11,000
10455012 SD260 45-75 6500-11,000
10455016 SD200 50-75 6000-11,900
10455017 SD200 50-75 6000-11,900
10455019 SD200 50-75 6000-11,900
10455021 SD200 55-85 6000-12,000
10455022 SD200 55-85 6000-12,000
10455024 SD250 45-74 8600-12,900
10455025 SD210 45-74 6000-11,000
10455044 SD200 52-76 6000-12,000
10455047 SD260 50-75 7000-11,000
10455049 SD200 52-76 3500-5000
10455702 N/A 45-90 3500-5000
10455704 N/A 45-90 3500-5000
10455706 OG195 90 3500
(1) Starter No-Load Test at 10 volts.