lemon-mirror:
Home >> Cadillac >> 1996 >> Seville SLS >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Keyless Entry System - Remote >> Transmitter Programming >> Analog Instrument Cluster

Analog Instrument Cluster

  1. Press OFF and WARM on climate control panel simultaneously. Instrument Panel Cluster (IPC) will light all telltales, then go blank. System is now in DIAGNOSTIC MODE. Press PASSENGER COOLER button until "RFA?" is displayed, then press FAN UP. If "RFA DATA?" is displayed, press FAN DOWN. If "RFA OVERRIDE?" is displayed, press FAN UP.
  2. If "RFA S00 NO OVERRIDE" is displayed, press FAN DOWN. If "RFA S01 PROGRAM FOB #I" is displayed, press FAN UP.
  3. IPC will show "0" on right side of Driver Information Center (DIC) display. Press warmer button on climate control until unit until "99" is displayed.
  4. Press and hold TRUNK button on transmitter. While holding TRUNK button, press LOCK button and hold for one second. Hold both buttons for a total of 3 seconds. Locks cycle when programming is complete. If transmitter is not programmed within 30 seconds after entering "99" override display, system will default and you must begin again at step 2).
  5. To program second transmitter, press FAN DOWN button until "RF S02 PROGRAM FOB #Z" is displayed, then press FAN UP. Repeat step 4). To exit system, press AUTO, MODE UP, MODE DOWN, or RESET.