lemon-mirror:
Home >> Cadillac >> 1997 >> Seville SLS >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System >> Description

Charging System: Description

NOTE: Generators on Eldorado, Concours, DeVille and Seville are controlled by Powertrain Control Module (PCM) or Instrument Panel Cluster (IPC). For system and related trouble code diagnosis, see GENERATOR & REGULATOR - DIAGNOSIS article.

The CS144 (Charging System) generators have a high amperage output. The 144 designation is the outside diameter of the stator laminations, measured in millimeters. CS series generators include a delta stator, rectifier bridge, and a rotor with slip rings and brushes. A built-in regulator incorporates fault detection circuitry. See Fig 1. A conventional pulley and external fan are used to cool slip ring end frame, rectifier bridge and regulator.

Most CS series generators operate with 2 wire connections and a ground path through the mounting bracket. The first wire connection is the BAT (output) terminal. This terminal must be connected to the battery during operation. The second wire connection is through the charge indicator light or an external resistor to terminal "L" of the regulator. This connection provides initial excitation at start-up.

Three other regulator terminals, "P", "F/I" and "S", are provided for optional use. Terminal "P" is connected to the stator and may be connected to a tachometer. Terminal "F/I" provides an alternative method for turning on the generator without going through the charge indicator light or external resistor. Terminal "S" may be used to sense electrical system voltage at a remote point on the vehicle. If terminal "S" is not used, the regulator senses internal generator voltage.

Regulated voltage varies with temperature. System limits voltage by controlling rotor field current while field current is on. Regulator switches rotor field current on and off at a fixed frequency of 400 cycles per second to help control radio noise. By varying overall on/off time, correct average field current for proper system voltage control is obtained. At high speeds, with lower electrical loads, on-time may be 10 percent of off-time. At low speeds, with higher electrical loads, on-time may be 90 percent of off-time. See the GENERATOR USAGE/AMP OUTPUT RATING  table.

Fig 1: Charging System Wiring Schematic CS144 Series
G95E35166Courtesy of GENERAL MOTORS CORP.
GENERATOR USAGE/AMP OUTPUT RATING

Application Generator RPO Code Rated Output
"E" & "K" Bodies CS144 KG9 140