lemon-mirror:
Home >> Cadillac >> 2000 >> DeVille Base >> Repair and Diagnosis >> Electrical >> Charging Systems >> On-Vehicle Testing >> Charge Indicator Light Inoperative

Charge Indicator Light Inoperative

  1. Perform GENERATOR FUNCTIONAL TEST  . Go to next step.
  2. Turn ignition off. Turn ignition on, engine off. Observe battery charge indicator light on instrument cluster during bulb check. If charge indicator light does not illuminate during bulb check, replace instrument cluster. See appropriate INSTRUMENT PANELS article in ACCESSORIES & EQUIPMENT. If charge indicator light illuminates during bulb check, problem is intermittent.