Fuel Injected Engines
- The ECM will set timing at a specified value when the "Test" terminal is grounded. To check EST operation, timing should be checked at 2000 RPM with the terminal not grounded.
- Ground the "Test" terminal. If timing changes at 2000 RPM, the EST is operating.