Delayed & Exit Illumination Modes
NOTE:
Instrument Panel (IP) brightness control switch may also be referred to as IP dimmer switch.
- Enter feature customization mode. See ENTER FEATURE CUSTOMIZATION MODE
. Turn IP brightness control switch to DOME position. Count number of chimes in order to determine current mode (1-4). See DELAYED & EXIT ILLUMINATION MODES
table.DELAYED & EXIT ILLUMINATION MODES
Mode Delayed Illumination Exit Illumination 1 Disabled Disabled 2 Enabled Disabled 3 Disabled Enabled 4 Enabled Enabled - To change mode, cycle IP brightness control switch from OFF position to DOME position to advance to next mode until desired mode is reached. Chime will sound number of times equivalent to mode. Chime indicator sequence will repeat after chime sounds for mode 4. Mode 4 is default mode.
- To exit and save current feature customization mode settings, turn ignition switch to LOCK position. Reinstall BCM PRGRM (10-amp) fuse.