Circuit/System Testing
- If any other IPC indicators or gages are inoperative, refer to Symptoms - Displays and Gages .
- Ignition OFF, disconnect the ECM harness connectors. Ignition ON, the lamp should not illuminate.
- If the lamp is illuminated, test the lamp control circuit for a short to ground. If the circuit tests normal, replace the IPC.
- Ignition ON, connect a 3A fused jumper wire between the lamp control circuit and ground. The lamp should illuminate.
- If the lamp does not illuminate, test the lamp control circuit for a short to voltage, or an open/high resistance. If the circuit tests normal, replace the IPC/bulb.
- If all circuits test normal, replace the ECM.