Fastener Specifications
Reusable Threaded Fastener Tightening Specifications
| Application | Specification |
|---|---|
| Metric (English) | |
|
NOTE:
All fasteners listed in this table can be reused after removal.
|
|
| Battery Bracket Bolt | 9 N.m (80 lb in) |
| Battery Fuse Block Nut | 6 N.m (53 lb in) |
| Battery Negative Cable Nut | 6 N.m (53 lb in) |
| Battery Negative and Positive Cable Ground Nut | 22 N.m (16 lb ft) |
| Battery Positive Cable Nut (Battery) | 22 N.m (16 lb ft) |
| Battery Positive Cable Nut (Starter) | 22 N.m (16 lb ft) |
| Battery Positive Cable Ground Bolt | 22 N.m (16 lb ft) |
| Battery Tray Retaining Bolt | 11.5 N.m (102 lb in) |
| Body Wiring Harness Cable Nut | 6 N.m (53 lb in) |
| Generator B (+) Nut | 14 N.m (124 lb in) |
| Generator Bolt | 22 N.m (16 lb ft) |
| Generator Nut | 22 N.m (16 lb ft) |
| Generator Stud | 9 N.m (80 lb in) |
| Starter Retaining Bolt | 22 N.m (16 lb ft) |