Rear Motor
Connect a jumper wire between RED terminal of center section and either RED-BLUE (RED-GRN Aries & Reliant) or YEL-BLUE (YEL-GRN Aries & Reliant) connection. Connect second jumper between BLK terminal in center section and open in rear section (front section Aries & Reliant). If motor does not operate, reverse first jumper connections. If motor still does not operate, either harness or three-motor assembly should be replaced.