lemon-mirror:
Home >> Chrysler >> 1982 >> Imperial >> Repair and Diagnosis >> General Information >> Basic Trouble Shooting >> Semi-Automatic Temperature Control >> Testing >> Electronic SATC Testing >> Ambient Sensor Testing

Ambient Sensor Testing

With sensor removed from socket, resistance should be between 255 and 335 ohms when ambient temperature is between 70° and 80°F. Do NOT apply meter test for more than 5 seconds and do NOT hold sensor in hand while testing.