lemon-mirror:
Home >> Chrysler >> 1983 >> Imperial >> Repair and Diagnosis >> Engine Performance >> System >> Combustion Control Computer >> Diagnosis & Testing >> Excessive Fuel Flow Test

Excessive Fuel Flow Test

  1. With air cleaner cover removed, turn key on. If fuel flows continuously from injectors, disconnect control pump connector.
  2. If fuel continues to flow, replace fuel control plate (pump, injectors, flowmeter).
  3. If fuel flow stops, problem is in computer. Substitute good computer and retest. If original proves defective, replace computer.