lemon-mirror:
Home >> Chrysler >> 1995 >> Cirrus LXi >> Repair and Diagnosis >> Brakes >> Traction Control >> Anti-Lock Brake System >> Component Testing >> Proportioning Valve

Proportioning Valve

NOTE: It is not necessary to remove Hydraulic Control Unit (HCU) from vehicle to remove proportioning valves. DO NOT  disassemble proportioning valves.
  1. Road test vehicle to determine faulty proportioning valve. Remove suspect proportioning valve from HCU. See PROPORTIONING VALVE IDENTIFICATION table. Using fitting with correct thread size, install Pressure Test Fitting (6805-1 or 6805-2) into outlet port of HCU. Install proportioning valve into pressure test fitting. Install Pressure Test Fitting (6805-3 or 6805-4) into outlet port of proportioning valve. Install brakeline to pressure test fitting.
  2. Install a Pressure Gauge (C-4007-A) into each pressure test fitting. Bleed pressure gauges to remove trapped air. Have an assistant hold brake pedal down to obtain reading on valve inlet gauge. Check reading on outlet gauge. Compare readings to specification. See BRAKE PRESSURE  table. If readings are not as specified, replace proportioning valve. Bleed affected brakeline.
PROPORTIONING VALVE IDENTIFICATION

Body Application (1) Split/Slope ID
JA 14" Wheel Disc/Drum 500 psi/.43 (2)*
JA 15" Wheel Disc/Drum 500 psi/.43 (2)*
(1) Split point is when proportioning valve changes rear brake pressure to prevent skidding. Slope is the pressure differential (percentage ratio) between front and rear brakes.
(2) Bar code label.
BRAKE PRESSURE

Master Cylinder Pressure (1) Split/Slope Slope Rear Brake Outlet Pressure
1000 psi 500 psi/.43 600-700 psi
(1) Split point is when proportioning valve changes rear brake pressure to prevent skidding. Slope is the pressure differential (percentage ratio) between front and rear brakes.