Power Mirror Motor
Disconnect power mirror switch connector. See POWER MIRROR SWITCH
under REMOVAL & INSTALLATION. Connect one end of a jumper wire to a 12-volt source and other end to specified power mirror switch connector terminals. See POWER MIRROR MOTOR TEST
table. Connect one end of another jumper wire to a good ground and other end to specified power mirror switch connector terminals. If mirror does not operate as specified, check for open or shorted circuit or replace power mirror assembly.
POWER MIRROR MOTOR TEST
| Apply 12 Volts To Terminal No. |
Ground Terminal No. |
Mirror Operation (Right) |
Mirror Operation (Left) |
| Switch Connector |
| 12 |
6 |
Up |
... |
| 13 |
1 |
... |
Up |
| 6 |
12 |
Down |
... |
| 1 |
13 |
... |
Down |
| 6 |
7 |
Right |
... |
| 1 |
8 |
... |
Right |
| 7 |
6 |
Left |
... |
| 8 |
1 |
... |
Left |
| Door Connector |
| 6 |
2 |
Up |
Up |
| 2 |
6 |
Down |
Down |
| 2 |
5 |
Right |
Right |
| 5 |
2 |
Left |
Left |
| 1 |
3 |
|
|