Integrated Power Module: Installation
NOTE:
When a replacement IPM is installed in the vehicle, the IOD fuse must be rotated to the "customer" position.
- Install battery connection and retaining nut. Tighten nut to 28 N.m (250 in. lbs.)
- Connect the electrical harness connectors to the Integrated Power Module (IPM).
- Position IPM into place, and lock into position.
- Install the hood cable retaining clip.
- Connect battery negative cable.