Charging System: Generator: Removal: 3.5L
- Disconnect battery negative cable.
- Remove the engine cover.
- Remove the generator drive belt.
- Remove the B+ terminal nut and wire. See Fig 1.
- Disconnect the generator field circuit wiring connector. See Fig 1. Push the RED locking tab to release.
- Remove the upper mounting bracket. See Fig 2.
- Remove the 2 lower mounting bolts. See Fig 3.
- Remove generator.