Cranking Test
NOTE:
Ensure battery is fully charged. Perform a battery load test and voltage drop test before proceeding.
- Connect an inductive ammeter clamp to positive battery cable. Connect voltmeter to battery. Disable ignition system by disconnecting coil pack electrical connector at coil pack.
- Crank starter and observe both meter readings. If readings are not within specification, repair or replace starter. See BENCH TESTING and appropriate STARTER SPECIFICATIONS table.