Installation Procedure
- Clean the sealing surfaces of the EBCM and the BPMV with denatured alcohol and allow to dry.
Install the EBCM (1) to the BPMV.
- CAUTION:
Refer to Fastener Caution .
Install the EBCM bolts (1) and tighten in a cross pattern to 3 N.m (27 lb in).
- Connect the EBCM electrical connector.
- Install the transfer case skid shield, if equipped. Transfer Case Skid Shield Replacement (NY7) , or Transfer Case Skid Shield Replacement (Bison)
- Program the EBCM. Control Module References