lemon-mirror:
Home >> Geo >> 1992 >> Tracker LSi, Automatic >> Repair and Diagnosis >> Electrical >> Starter - Reduction Gear >> Bench Testing >> Starter Component Inspection >> Commutator

Starter Component Inspection: Commutator

  1. Using "V" blocks and dial indicator, check commutator runout (out-of-round). Ensure runout is not more than .002"(.05 mm). Turn commutator/armature on lathe until runout (out-of-round) is within specification.
  2. Check diameter commutator. Commutator should not be less than specification. See MINIMUM COMMUTATOR SPECIFICATIONS . If commutator is cut down more than .008" (.20 mm), undercut insulating mica to depth of .015-.031" (.38 -.78 mm).
MINIMUM COMMUTATOR SPECIFICATIONS

Application In. (mm)
Metro (A/T) 1.06 (27)
Prizm 1.14 (29)
Storm
A/T 1.14 (29)
M/T 1.06 (27)
Tracker 1.13 (28.8)