Ignition System: Overhaul: Disassembly
- Remove all spark plug wires and vacuum hoses from the distributor. Remove distributor cap. Remove the condenser ground wire, and disconnect pulse generator/ignitor wire connector from distributor. Remove hold-down bolt, lifting distributor from cylinder head.
- Carefully pry upward on reluctor with 2 screwdrivers, cushioned with rags to prevent damage to distributor housing. Refer to Fig 1. Use care not to damage reluctor or stator.
- Remove vacuum advance diaphragm mounting screw. Pull out on diaphragm unit, while lifting up on end of diaphragm arm.
- Drive roll pin from distributor shaft. Remove shaft and gear from housing. Inspect and replace parts as necessary.