Ignition Wire Resistance
Carefully remove wires by pulling on their rubber boots. Do not bend wire or conductor may be broken. Check for corroded condition, cleaning if necessary. Connect ohmmeter probes (set in x1000 scale) to each end of ignition wires. Resistance reading should be less than 25,000 ohms. If not, replace wires.