Two-Way Valve
- Remove fuel filler cap and remove vapor hose from fuel tank to two-way valve. Connect vacuum/pressure pump with gauge to hose and slowly draw vacuum while observing gauge.
- Vacuum should stabilize at .2-.6 in. Hg as two-way valve opens. Reverse pump and gauge connections and slowly pressurize vapor hose. Pressure should momentarily stabilize at 1.0-2.2 in. Hg. If not, check hose connections for leaks. If hose connections are okay, replace valve and retest.