CKP Sensor Replacement
- Disconnect the CKP sensor 3P connector.
- Remove the CKP sensor (A).
- Install the sensor in the reverse order of removal with a new O-ring (B).
- Do the CKP pattern clear/CKP pattern learn procedure (see CKP PATTERN CLEAR/CKP PATTERN LEARN ).