Installation Procedure
- Install the longitudinal accelerometer.
- Install the longitudinal accelerometer retaining screws.
Tighten: Tighten the screws to 2 N.m (18 lb in).
- Install I/P bezel. Refer to Instrument Panel Center Trim Panel Replacement in Instrument Panel, Gages and Console.
NOTE:
Refer to Fastener Notice
in Cautions and Notices.